ABB
1SBL241024R8510UA26-30-10RA (50HZ) 380-400 (60HZ) 400-415
UA26-30-10RA (50HZ) 380-400 (60HZ) 400-415
Contactor for cap. bank switching with 3 series damping resistors - ABB (UA series) - UA26-30-10RA (50HZ) 380-400 (60HZ) 400-415 - 3-poles (3P) - Reactive power switching capacity 22kVAr (400/415Vac) - Control coil voltage 380Vac-400Vac (50Hz) / 400Vac-415Vac (60Hz) - with 1NO aux. contact - Screw-clamp connections - Mounting on DIN rail or surface (54mm width)
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
1SBL241024R8510
Online Price
RM 790.00
Discount
50.0%
Net Price
RM 395.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
ABB - UA series capacitor switching contactors1SBL241024R8510
Description
Contactor for cap. bank switching with 3 series damping resistors - ABB (UA series) - UA26-30-10RA (50HZ) 380-400 (60HZ) 400-415 - 3-poles (3P) - Reactive power switching capacity 22kVAr (400/415Vac) - Control coil voltage 380Vac-400Vac (50Hz) / 400Vac-415Vac (60Hz) - with 1NO aux. contact - Screw-clamp connections - Mounting on DIN rail or surface (54mm width)
Specifications
Primary brand
ABB
Main function
Contactor
Product series / family name
UA series
Sub-range name
UA26 contactors
Functions
Contactor for cap. bank switching
Design
3 series damping resistors
Poles
3-poles (3P)
Rated current
Unlimited Ipeak (thanks to series resistors during starting phase)
Rated reactive power (kVAr)
12.5kVAr (230/240Vac; AC-6b; 40°C; 50/60Hz)
11.5kVAr (230/240Vac; AC-6b; 55°C; 50/60Hz)
9kVAr (230/240Vac; AC-6b; 70°C; 50/60Hz)
22kVAr (400/415Vac; AC-6b; 40°C; 50/60Hz)
15.5kVAr (400/415Vac; AC-6b; 70°C; 50/60Hz)
20kVAr (400/415Vac; AC-6b; 55°C; 50/60Hz)
24kVAr (440Vac; AC-6b; 40°C; 50/60Hz)
20kVAr (440Vac; AC-6b; 55°C; 50/60Hz)
17kVAr (440Vac; AC-6b; 70°C; 50/60Hz)
30kVAr (500/550Vac; 40°C; 50/60Hz)
25kVAr (500/550Vac; AC-6b; 55°C; 50/60Hz)
20kVAr (500/550Vac; AC-6b; 70°C; 50/60Hz)
35kVAr (690Vac; AC-6b; 40°C; 50/60Hz)
31kVAr (690Vac; AC-6b; 55°C; 50/60Hz)
26kVAr (690Vac; AC-6b; 70°C; 50/60Hz)
11.5kVAr (230/240Vac; AC-6b; 55°C; 50/60Hz)
9kVAr (230/240Vac; AC-6b; 70°C; 50/60Hz)
22kVAr (400/415Vac; AC-6b; 40°C; 50/60Hz)
15.5kVAr (400/415Vac; AC-6b; 70°C; 50/60Hz)
20kVAr (400/415Vac; AC-6b; 55°C; 50/60Hz)
24kVAr (440Vac; AC-6b; 40°C; 50/60Hz)
20kVAr (440Vac; AC-6b; 55°C; 50/60Hz)
17kVAr (440Vac; AC-6b; 70°C; 50/60Hz)
30kVAr (500/550Vac; 40°C; 50/60Hz)
25kVAr (500/550Vac; AC-6b; 55°C; 50/60Hz)
20kVAr (500/550Vac; AC-6b; 70°C; 50/60Hz)
35kVAr (690Vac; AC-6b; 40°C; 50/60Hz)
31kVAr (690Vac; AC-6b; 55°C; 50/60Hz)
26kVAr (690Vac; AC-6b; 70°C; 50/60Hz)
Rated operating voltage (Ue)
690 V
Rated impulse voltage (Uimp)
8 kV
Rated insulation voltage (Ui)
(IEC/VDE) 1000 V
(UL/CSA) 600 V
(UL/CSA) 600 V
Connection type
Screw-clamp connections
Short circuit withstand current (Icw)
125A / 0.125kA
Control Voltage (AC)
380Vac-400Vac (50Hz)
400Vac-415Vac (60Hz)
400Vac-415Vac (60Hz)
Net Height (mm)
120 mm
Net Width (mm)
54 mm
Net Depth (mm)
126.3 mm
Mounting mode
Mounting on DIN rail or surface
Normally Open (NO) auxliary contacts
1 NO contacts
Normally Closed (NC) auxiliary contacts
0 NC contacts
Order code / Manufacturer SKU
UA26-30-10RA (50HZ) 380-400 (60HZ) 400-415
Manufacturer product status
Commercialized
Equivalent to
UA263010RA50HZ38040060HZ400415
Compliant with standard(s)
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60529
GOST
CCC (GB/T 14048.4-2010)
IEC/EN 60947-4-1
IEC/EN 60529
GOST
CCC (GB/T 14048.4-2010)
Benefits
ABB offers 2 contactor versions according to the value of the inrush current peak and the power of the capacitor bank.
UA..RA contactors for capacitor switching (UA16..RA to UA110..RA) with insertion of damping resistors. The insertion of damping resistors protects the contactor and the capacitor from the highest inrush currents.
UA contactors for capacitor switching (UA16 to UA110). Maximum permissible peak current I ≤ 100 times the nominal rms current of the switched capacitor.
UA..RA contactors for capacitor switching (UA16..RA to UA110..RA) with insertion of damping resistors. The insertion of damping resistors protects the contactor and the capacitor from the highest inrush currents.
UA contactors for capacitor switching (UA16 to UA110). Maximum permissible peak current I ≤ 100 times the nominal rms current of the switched capacitor.
Operating rate
(at no load) 3600 Cycles/hour
Connection type
(Main terminals) Screw M4
(Coil terminals) Screw M3.5
(Built-in auxiliary terminals) Screw M4
(Coil terminals) Screw M3.5
(Built-in auxiliary terminals) Screw M4
Related Documents
Name | Last Update | Language |
---|---|---|
ABB - A9 AF1650 contactors - Catalog.pdf | 12 Dec 2021 | English (US) |
ABB - Across the line contactors - Catalog.pdf | 12 Dec 2021 | English (US) |
ABB - Contactors - Catalog.pdf | 13 Oct 2022 | English (US) |